The R-410A phase-down and what R-454B means for an AC replacement

You can keep repairing an R-410A air conditioner or heat pump for as long as it lasts, including replacing the outdoor unit. What you can no longer do is have a whole new R-410A system installed. New residential systems now use refrigerants with a much lower global warming potential, mainly R-454B and R-32.

What the rule is

The American Innovation and Manufacturing Act of 2020 tells the EPA to phase down hydrofluorocarbons by 85 percent from historic baseline levels by 2036. One of the ways the EPA does that is sector by sector. For residential and light commercial air conditioning and heat pump systems, mini-splits and unitary systems included, the EPA set a global warming potential limit of 700 with an installation compliance date of January 1, 2025. Its table carves out systems whose specified components were all manufactured or imported before that date.

R-410A, the refrigerant in most systems installed over the last couple of decades, is listed by the EPA with a GWP of 2,090. It does not come close to the limit.

The refrigerants in new equipment

Figures from the EPA's SNAP list of substitutes for residential and light commercial air conditioning and heat pumps.
RefrigerantGlobal warming potentialASHRAE safety class
R-410A2,090A1
R-32675A2L
R-454B470A2L

Both replacements are classed A2L, a step up in flammability from A1, and the EPA lists them as acceptable with use conditions. That is the reason new equipment is built differently and the reason you cannot pour a new refrigerant into an old system. An R-410A system stays an R-410A system for its whole life.

Repair or new system: where the EPA draws the line

The EPA's own answers to homeowners are direct. "Homeowners can maintain and repair their systems throughout the useful life of the equipment. A homeowner can replace a faulty component (e.g., condensing unit, indoor coil, other smaller parts) with a similar R-410A component." And: "After January 1, 2026, if a whole new system is installed it must use lower-GWP refrigerant."

What counts as a new system? For a residential split system, the EPA says it is one installed in a newly built home, or one where both the condensing unit and the indoor coil are replaced together. Keeping the old refrigerant lines does not change that: replace both ends and it is a new system.

Manufacturers may keep making R-410A parts. Condensing units, compressors and evaporators made after January 1, 2025 have to be labeled "for servicing existing equipment only", and there is no end date on selling them. The EPA does add a caution worth heeding: the availability of HFCs and components may lessen over time as the phase-down continues.

What that means at the kitchen table

If your system is working: do nothing. There is no requirement to replace anything.

If one half has failed: a like-for-like R-410A outdoor unit or coil is still a legal repair. Ask the contractor what the part costs now and whether they expect to be able to get it, then weigh that against the age of the other half.

If you are replacing the whole thing: it will be R-454B or R-32 equipment. The outdoor unit and indoor coil have to be a matched pair designed for that refrigerant. Ask whether the existing line set is being reused or replaced and why.

Who may handle the refrigerant

Under Section 608 of the Clean Air Act, technicians who maintain, service, repair or dispose of equipment that could release refrigerant must be certified, by passing an EPA-approved test. The EPA says the credential does not expire. In Texas the company also needs a TDLR air conditioning contractor license. Asking for both is not rude; it is Tuesday for a good contractor.